Host High Speed Electrical Test Procedure Revision 1.4
18. If cursors measurement is enabled on the oscilloscope place the two vertical cursors around one
test packet, one just (about one bit time) before the sync field and the other just (about one bit
time) after the EOP (END OF PACKET). Refer to the following figure. Press OK on the USB2
application dialog box to begin acquisition and analysis of the test packet.
Figure 6: High-speed Test Packet
19. Verify that the Signal Eye, EOP Width, and Signaling Rate all pass.
Figure 7: HTML Report for High Speed Signal Quality Test
16