Commands Listed in Alphabetical Order
Conditions
This command re
quires a DPO2AUTO application m odule.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:CAN{:I Dentifier|:ADDRess}:MODe
{STandard|EXTended}
TRIGger:A:BUS:B<x>:CAN{:I Dentifier|:ADDRess}:MODe?
Arguments
STandard species the standard addressing mode.
EXTended species the e xtended addressing mode.
TRIGger:A:BUS:B<x>:CAN{:IDentier|:ADDRess}:VALue
Sets or returns the binary address string used for a CAN trigger if the trigger
condition is ID or IDANDDATA. Applies to b us <x>, where x is the bus number.
Conditions
This command requires a DPO2AUTO application m odule.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:CAN{:I Dentifier|:ADDRess}:VALue <QString>
TRIGger:A:BUS:B<x>:CAN{:I Dentifier|:ADDRess}:VALue?
Arguments
<QString> is up to 29 bits specifying the binary CAN identier value. The only
allowedcharactersinthe
QString are0,1,andX.
Examples
TRIGGER:A:BUS:B1:CAN:IDEN TIFIER:VALUE 1011 sets the CAN trigger
identier value to 1011.
TRIGger:A:BUS:B<x>:I2C:ADDRess:MODe
Sets or returns the I
2
C address mode to 7 or 10-bit. Applies to bus <x>, where x
is the bus number.
Conditions
This command requires a DPO2EMBD application module.