Commands Listed in Alphabetical Order
Group
Bus
Syntax
BUS:B<x>:SPI{:CLOCK|:SCLK} :SOUrce {CH1|CH2|CH3|CH4|
D0|D1|D2|D3|D4|D5|D6|D7|D8 |D9|D10|D11|D12|D13|D14|D15}
BUS:B<x>:SPI{:CLOCK|:SCLK} :SOUrce?
Arguments
CH1-CH4 is the channel to use as the SPI SCLK source.
D0-D15 is the digital channel to use as the SPI SCLK source.
BUS:B<x>:SPI:DATA{:IN|:MISO}:POLARity
Sets or returns the SPI MISO polarity for bus <x>, where x is the bus number.
Conditions
This command requires
a DPO2EMBD application module.
Group
Bus
Syntax
BUS:B<x>:SPI:DATA{:IN|:MIS O}:POLARity {LOW|HIGH}
BUS:B<x>:SPI:DATA{:IN|:MIS O}:POLARity?
Arguments
LOW species an active low polari
ty.
HIGH species an active high polarity.
BUS:B<x>:SPI:DATA{:IN|:MISO}:SOUrce
Sets or returns the SPI MISO source for bus <x>, where x is the bus number.
Conditions
This command requires a DPO2EMBD application module.
Group
Bus
Syntax
BUS:B<x>:SPI:DATA{:IN|:MIS O}:SOUrce {CH1|CH2|CH3|CH 4|
D0|D1|D2|D3|D4|D5|D6|D7|D8 |D9|D10|D11|D12|D13|D14|D15}
BUS:B<x>:SPI:DATA{:IN|:MIS O}:SOUrce?
MSO2000B, DPO2000B, MSO2000 and DPO2000 Series Oscilloscopes Programmer Manual 2-87