Commands Listed in Alphabetical Order
MEASUrement:
REFLevel:ABSolute:HIGH
Sets or returns the high reference level, and is the upper reference level when
MEASUrement:REFLevel:METHod is set to Absolute. This command affects the
results of ri
se and fall measurements.
NOTE. this command affects the associated reference level parameter for all
MEASurements:IMMed and the four periodic measurements.
Group
Measurement
Syntax
MEASUrement:REFLevel:ABSo lute:HIGH <NR3>
MEASUrement:REFLevel:ABSo lute:HIGH?
Related Commands
MEASUrement:REFLevel:METHod, MEASUrement:IMMed:TYPe,
MEASUrement:MEAS<x>:TYPe
Arguments
<NR3> is the high reference level, in volts. The default is 0.0 V.
Examples
MEASUREMENT:REFLEVEL:ABSO LUTE:HIGH 1.71 sets the high reference level
to 1.71 V.
MEASUREMENT:REFLEVEL:ABSO LUTE:HIGH? might return
:MEASUREMENT:REFLEVEL:ABS OLUTE:HIGH 1.7100E+00 indicating that the
absolute high reference level is set to 1.71 V.
MEASUrement:REFLevel:ABSolute:LOW
Sets or returns the low reference level, and is the lower reference level when
MEASUrement:REFLevel:METHod is set to Absolute.
NOTE. this command affects the associated reference level parameter for all
MEASurements:IMMed and the four periodic measurements.
Group
Measurement
Syntax
ME
ASUrement:REFLevel:ABSolute :LOW <NR3>
MEASUrement:REFLevel:ABSo lute:LOW?